CORE N: A New-Generation Panel for WC Cubicles and Lockers
Explore CORE N within the SANDER panel solutions family, including its applications, panel properties, system components and technical assessment criteria. This page explains the product’s positioning and application limits for architectural projects and material selection.

COMPACT CORE N
Architectural Wet-Area Panel System
Compact Core N, is a high-performance compact laminate panel developed for demanding wet-area conditions.
Developed for architectural applications where durability, hygiene and visual simplicity are required together. It offers structural stability and long-term resistance to moisture, impact and intensive use.
Architectural Qualities
- Clean, simple surface appearance
- Controlled colour consistency
- Reduced visibility of joint lines
- Design compatible with system integrity
- Long-term architectural integrity
Technical Strengths
- High-density, solid compact structure
- 100% moisture-resistant core
- Impact and wear resistance
- Suitable for high-traffic areas
CORE N Panel Stock Colours
Explore the colour chart for options that suit your architectural material palette. Confirm current stock and lead times with our team.
View Colour Chart — PDFWet areas cannot be assessed solely on aesthetic expectations in architectural projects. WC cubicles, changing areas and shower cubicles are exposed to high daily user traffic, frequent door opening and closing, cleaning chemicals, varying humidity and, in some areas, direct water contact. Panel systems used in these environments must therefore be assessed not only by their initial appearance, but by their long-term behaviour, ability to retain their form and maintenance requirements. SANDER’s approach distinguishes wet areas according to usage conditions rather than treating them as one uniform environment.
CORE N, under standard usage conditions:
Maintains long-term dimensional stability.
Does not cause misalignment in doors and panels.
Is compatible with daily cleaning and hygiene procedures.
Particularly in areas such as WC cubicles with high user traffic, frequent door opening and closing, and intensive cleaning, CORE N provides consistent, predictable performance and a reliable reference for projects.
THE DEFINED LIMIT OF CORE N
In SANDER’s approach, every product has a defined area of appropriate use. CORE N is not positioned for shower cubicles exposed to direct, continuous water contact.
This is not a weakness; it is a deliberately defined technical boundary. When conditions exceed standard use, a different solution is introduced.
Shower cubicles are among the most demanding wet areas. Continuous water contact, high humidity and mechanical stress take these areas beyond standard applications. At this point, SANDER COMPACT CORE X becomes a complementary part of the system.
CORE X: Adds performance and a safety margin to surfaces exposed to continuous water contact, areas with higher durability requirements and applications subject to greater mechanical stress.
CORE X is not an alternative to CORE N.
CORE X is a complementary solution used only where standard limits are exceeded.
With this approach:
Unnecessary cost increases are avoided.
Higher performance is specified only where needed.
The project budget is balanced on technical grounds.
SANDER does not assess compact panel solutions as standalone panel products. The panel is considered as one system together with hinges, locks, legs, connection profiles and installation details.
THE STANDARD PANEL CONCEPT | CORE N POSITIONING
Every architectural project needs a standard panel solution that simplifies design and installation, minimises risks and avoids unexpected issues on site.
SANDER COMPACT CORE N directly meets this need. CORE N
is positioned as the primary panel solution used with confidence in the majority of projects, drawing on SANDER’s extensive field experience.
MATERIAL REFERENCE
CORE N panel density: 1150 kg/m³. This value is a SANDER product declaration and must be confirmed against the current technical documentation for the panel selected for the project and order.
SANDER’s panel approach treats the panel as a functional component, not simply a surface.
SYSTEM INTEGRITY
Panel performance
is not meaningful in isolation unless assessed together with hinges, locks, legs and connection profiles.
Designed to balance load distribution.
Designed as an integrated whole supporting long-term stability.
CORE N is the standard, reliable primary solution for the majority of architectural projects.
CORE X is the complementary option for shower cubicles and special conditions where that standard is insufficient.
The technical positioning and application limits of the SANDER Compact Core N panel are based on performance criteria defined in international standards for compact laminate product groups and technical assessments of wet-area applications.
Within this framework, technical expectations under TS EN 438 (Core X Compact Laminate) for dimensional stability, surface durability, chemical resistance and emissions have been assessed against the product’s intended application. Compact Core N is designed with the humid indoor conditions anticipated in shared WC cubicle and locker applications in mind.
During technical assessment, panel thickness and tolerances have been considered for long-term stability in humid interiors. Surface properties have been developed around resistance to cleaning chemicals, scratches and stains. Formaldehyde emissions are also controlled in line with healthy indoor use requirements.
Under this approach, Compact Core N is assessed for reliable use in indoor WC cubicle applications in shopping centres, schools, offices, hospitals and similar facilities.
The product’s application limits are defined with the same technical transparency. Compact Core N is not designed around continuous, direct water pressure. Shower cubicles and applications involving constant water contact must therefore be considered outside its scope.
This technical boundary reflects engineering and performance criteria defined for the intended application, rather than material quality. SANDER’s approach positions products through appropriate application definitions and clear performance expectations, as well as technical values.
Technical specifications and TS EN standards
TECHNICAL SPECIFICATIONS AND PERFORMANCE CRITERIA
COMPACT CORE N
Harmonised Standard: TS EN 13986
| ASSESSMENT CRITERION | TEST STANDARD | UNIT / TECHNICAL VALUE | THICKNESS RANGE (mm, nominal) |
|---|---|---|---|
| Tolerances relative to nominal dimensions | TS EN 14323 | mm | 9 < t ≤ 12 |
| Thickness tolerance relative to the nominal value | TS EN 14323 | mm | According to TS EN 14322, Table 14-2 |
| Actual panel thickness | TS EN 14323 | mm | Class ≤ +0.5 / −0.3 mm Difference between maximum and minimum values ≤ 0.6 mm |
| Length and width | TS EN 14323 | mm | ±5 |
| Deviation from flatness | TS EN 14323 | mm/m | ≤ 2 |
| Edge damage | TS EN 14324 | mm | ≤ 10 |
| Surface defects | TS EN 14323 | mm²/m² | Spot defects ≤ 2 Linear defects ≤ 20 |
| Scratch resistance | TS EN 14323 | N | ≥ 1.5 |
| Stain resistance | TS EN 14323 | class | ≥ 3 |
| Crack resistance | TS EN 12460-5 | Class | Class 3A |
| Wear resistance | TS EN 12460-1 | mg/100 g | Class 1 ≤ 50 |
| Formaldehyde emissions | TS EN 12460-1 | mg/100 g | ≤ 8 (E1) |
The current technical data sheet and test reports for the selected panel must form the basis of project specifications and order assessment. The test standard assignments in this table must also be confirmed against the relevant product documents.
Request technical information and a quotation for your project
SANDER CORE N Product and Technical Information
Review applications, usage limits, accessory integration and pre-project technical assessment topics in the CORE N product sheet prepared by SANDER.
SANDER CORE N Product Sheet — PDFRequest Technical Documentation from SANDER
The product sheet is a draft for technical approval; it is not an independent test report or certificate. Numerical values for the project and the relevant document scope must be confirmed before ordering.